The engineer teach me how to manage coal gas furnace


I am a new employee, the manager arranged me to operate the gas furnace, but I have nothing about the operation and management of the gas furnace , luckily, an engineer of  gas furnace manufacture huangtai gas furnace company have a lesson to me ,I quickly wrote what the experts said. The operation and management of gas furnace are as follows:

To ensure safety and produce high quality gas, making the furnace run at normal state, employees at all levels should strictly operate and manage the running gas furnace according to the Safety regulations for technical operations.

(一) Furnace control 

1. saturation temperature accurately  to be chosen according to the fuel, gasification intensity and the furnace condition , when the above points under the condition of steady, to stabilize the saturation temperature, when with automatic control, Note that if the actual value and set value close to.

2. control all levels temperature strictly: if the upper temperature can add coal to make it lower as possible,under150.

3. watch the furnace every two hours, the steps and notes:

First: open the steam valve of fire probing hole, and then open the cover of fire probing hole, and adjustment the seal steam to the appropriate value. Steam is too small to sealed, and gas spillover. If the steam is too big making the top part of the gas water vapor content increase, it will lead to the pressure fluctuation in the furnace.
Four crowbars insert furnace. One of the crowbars measures the middle needle, measurement the intermediate level of the furnace, the other measures edge stitch, Measuring the edge levels of furnace, burn drilling steel for two minutes ,
After observe the furnace, if you find there is something abnormal, please handle it timely, making it return to normal.
After observe the furnace, you should cover the furnace hole, and then close the steam valve.